Jumo PC Audit Trail Manager Software PCAT (B 70.9704.0) Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Oprogramowanie Jumo PC Audit Trail Manager Software PCAT (B 70.9704.0). JUMO PC Audit Trail Manager Software PCAT (B 70.9704.0) User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Operating Manual

PC Audit Trail ManagerSoftwarePCATB 70.9704.0Operating Manual12.05/00420786

Strona 2

2 PC Audit Trail Manager Software102.2 Minimum configurationThe following hardware and software requirements have to be met forinstalling and operatin

Strona 3 - Contents

113 InstallationAdministrator3.1 Starting the installationRun installationprogramh Start Microsoft Windowsh Place the CD in the drive and close the do

Strona 4

3 Installation12h Select the components that need to be installed.h Now enter the required license numbers.h Enter the path for the directory in which

Strona 5 - 1 Introduction

133 Installation3.2 Selecting the installation optionh Decide on an installation option.h Enter the path and file name for the user list.Administrator

Strona 6

3 Installation143.3 Carrying out the installationh The final action is to click on the button, to initiate the actual installation.The selected soft

Strona 7

154 Log-in to the programWhen the program has been started, you must log in.Enterpasswordh Log in to the program. Select your name and enter the passw

Strona 8

4 Log-in to the program16

Strona 9 - 2.1 General

175 User interface5.1 Elements of the user interfaceMenu bar The individual functions of the software can be started by using the menu bar. v Chapter

Strona 10 - 2.2 Minimum configuration

5 User interface18Navigation tree The individual PC software components for which audit trail entries aredocumented are listed in the navigation tree.

Strona 11 - 3 Installation

196 Navigation tree, Click on the “+” or “-” symbol with the left mouse button (single click), ordouble-click on a name, and then the list is expande

Strona 13

6 Navigation tree20Right mouse buttonA click with the right mouse button will produce the following functions:Information The “Information” function w

Strona 14

216 Navigation treeFilterFilter!resetThis function restores the filter list to its original state; self-defined filters aredeleted.Name fieldfor new f

Strona 16

237 Message windowThe message window shows all the audit trail entries that have been selectedin the navigation window.7.1 Altering the column widthIf

Strona 17 - 5 User interface

7 Message window247.2 Altering the row heightIf you position the mouse pointer between two rows and hold the left mousebutton down, you can alter the

Strona 18

257 Message window7.4 Marking rowsThe “Marking rows” function corresponds exactly to the function “Markingcolumns” on page 24, with the difference tha

Strona 19 - 6 Navigation tree

7 Message window26You can alter dates as follows:After all dates have been entered, the indication of the audit trail entries has tobe updated via the

Strona 20

278 Documenting audit trail entriesAt this point, it is worth remembering that there are two types of audit trailentries: - audit trail entries for th

Strona 21

8 Documenting audit trail entries28

Strona 22

299 Menu functions and toolbar9.1 FilePrint With this function you can start printing all displayed audit trail entries.If you only want to print out

Strona 23 - 7 Message window

Contents1 Introduction 51.1 Preface ... 51.2

Strona 24

9 Menu functions and toolbar309.3 DatabaseSwap outaudit trailThe more audit trail entries are contained in the database and displayed in themessage wi

Strona 25

319 Menu functions and toolbarOpen swapped out databaseThis function switches swapped out or external audit trail entries into displayagain in the mes

Strona 26

9 Menu functions and toolbar329.5 ViewInformation You can use this function to show or hide information in the message window.Error You can use this f

Strona 27 - 8.2 Creating a PDF file

339 Menu functions and toolbarMultiple lines This function switches the multiple-line view in the message window on or off.With multiple-line view, th

Strona 28

9 Menu functions and toolbar34

Strona 29 - 9 Menu functions and toolbar

3510 Options at program startWhen you start up the PC Audit Trail Manager software, you have theopportunity of setting various options when you log in

Strona 30

10 Options at program start36

Strona 31

3711 IndexAAdministrator 9, 11, 13CColumn widthalteration 23reset 23–24Comment in audit trail 31Commissioning 5Copy 29Creating a PDF file 27DDefault s

Strona 32

11 Index38MMark all 29Marking an area 25Marking columns 24Marking rows 25Menu bar 17Message window 18, 23Multiple lines 33NNavigation tree 17–18Naviga

Strona 33

3911 IndexSScreen texts 7Swap out audit trail 30TToolbar 17UUpdate 33User list 13WWarning signs 6Warnings 18–20, 32Warranty 5Working area 17

Strona 34

Contents9 Menu functions and toolbar 299.1 File ...

Strona 39 - 11 Index

JUMO GmbH & Co. KGStreet address:Moltkestraße 13 - 3136039 Fulda, GermanyDelivery address:Mackenrodtstraße 1436039 Fulda, GermanyPostal address:36

Strona 40

51 Introduction1.1 PrefacePlease read this operating manual before commissioning the software. Keepthe manual in a place that is accessible to all use

Strona 41

1 Introduction61.2 Arrangement of the documentationThe documentation for this software is addressed to equipment manufacturers(OEMs) and users with ap

Strona 42

71 IntroductionRepresentationh + EKeysKeys are shown in a box. Both symbols and text are possible. If a key has amultiple function, then the text show

Strona 43

1 Introduction8

Strona 44 - JUMO Process Control, Inc

92 PC Audit Trail Manager Software2.1 GeneralThe PC Audit Trail Manager software (PCAT) documents actions performed inthe PC software components, whic

Komentarze do niniejszej Instrukcji

Brak uwag